Before you buy

Why barriers need routine attention

An automatic barrier is moving machinery that may operate hundreds of times a day in all weathers. Springs lose tension, fixings loosen, loops in the road surface crack and safety devices drift out of alignment. None of this is unusual, but left unchecked it leads to breakdowns, unsafe operation or a barrier stuck open.

MSME Security recommends a routine service at least once a year to test components, lubricate moving parts and check safety features. Busy entrances, such as logistics yards or shared car parks, often benefit from more frequent visits. The manufacturer's instructions for the specific barrier should also guide the interval.

Read about our automatic barrier service
Red and white automatic rising arm barrier across a vehicle entrance

Budget guide

Typical UK guide figures for barrier upkeep

Broad UK market ranges to help with budgeting. Parts, access and the number of barriers on site all affect the final cost.

Routine service visit
£150 to £400 per barrier
Inspection, adjustment, lubrication and safety device testing.
Replacement barrier arm
£150 to £600
Depending on length, material, lights or skirts, plus fitting.
Replacement induction loop
£300 to £800
Cutting a new loop into the surface and connecting it to the detector.
Reactive call-out and diagnosis
£90 to £250
An engineer visit to find a fault, with parts charged separately.

These are typical UK guide figures excluding VAT and are not MSME Security prices or contract rates. Ask for a written scope of what each service includes.

What a service visit should check

A thorough service looks at the mechanics, the electrics and the safety systems, then tests the barrier as drivers will use it. Ask your engineer for a short report so you have a record of each visit.

  • Mechanism and balance

    Springs, gearbox, arm fixings and balance are checked and adjusted, and moving parts lubricated.

  • Safety devices

    Photocells, safety edges and vehicle detection are tested to make sure the arm will not lower onto a vehicle or person.

  • Loops and detection

    Induction loops and detectors are tested for reliable detection and checked for cracks in the surface.

  • Controls and access

    Keypads, readers, intercoms and number plate recognition are tested, and manual release is confirmed to work.

  • Electrics and cabinet

    Wiring, connections, control board and the cabinet seal are inspected for damage, damp or wear.

  • Arm and signage

    The arm, any lights or skirts and warning signs are checked for damage and visibility.

Common barrier faults

Most call-outs come down to a handful of causes. Recognising them helps you describe the problem when you report it and sometimes points to a simple fix, such as a blocked photocell.

  • Arm struck or snapped by a vehicle, often at busy or poorly lit entrances.
  • Barrier stays open or will not close because a photocell is dirty, blocked or misaligned.
  • Barrier opens on its own or fails to detect vehicles because a loop is damaged.
  • Slow or jerky movement from worn springs, lack of lubrication or a tired motor.
  • Fobs, keypads or number plate recognition not opening the barrier after a power or network interruption.
  • Water ingress into the cabinet causing intermittent faults after heavy rain.

Keeping downtime to a minimum

Make sure staff know how to use the manual release safely, so vehicles can still get in and out during a fault. For an entrance that the business relies on, consider keeping a spare arm on site. Record faults with dates and times, as patterns help an engineer find the cause faster.

If your barrier is old, repeated repairs can cost more than replacement. A site inspection can tell you whether servicing and parts will keep it reliable or whether a new barrier is the better value.

FAQs

Barrier servicing and maintenance: frequently asked questions

How often should an automatic barrier be serviced?

We recommend at least once a year. Barriers that move very frequently, such as at busy yards or shared car parks, often need more regular visits, guided by the manufacturer's instructions.

Why does my barrier stay up and refuse to close?

Often a safety device or loop thinks something is still in the lane. A dirty or misaligned photocell or a damaged loop are common causes, and an engineer can test each one.

Can you service a barrier that someone else installed?

Speak to us about your barrier. An engineer can inspect it, check its condition and advise on servicing, repairs or replacement.

Barrier playing up or due a service?

Talk to an engineer about servicing, repairs or whether replacement is better value.

Free site inspection

Arrange barrier servicing or repairs

Tell us the barrier make if you know it, how often it is used and any faults you have noticed.

Call Chase Dobbie and the team01332 492002

Or email info@msmesecurity.co.uk

  • Monday to Friday: 9am to 6pm
  • Saturday and Sunday: 11am to 5pm

Fields marked * are required. We only use your details to respond to your enquiry.

Call nowGet a quote